Single – Double Wing Emergency Exit Door

Single – Double Wing Emergency Exit Door

It is used in situations where emergency exit from interior areas is required. It is used when large sized products need to be removed from the inside. Only opens from the inside. Case thickness is 4 cm.

PDF Download

GENERAL FEATURES

PRODUCT FEATURES

FEATURESVALUES
Door Wing40(+/- 2) density polyurethane was injected between two sheets without using any wood material.
Door ThicknessFor cold room 68 mm, for freezer room 92 mm’dir.
Door LockIt is imported, has the feature of opening from the inside when locked and the anti-panic arm is phosphorescent.
Door HingeUpgradeable and adjustable
Surface Sheets Both sides of the standard manufacturing surface are PVC sheet. Optionally, it can be polyester painted sheet or CrNi.
Door FrameFor industrial panel rooms, one wall of the room is produced as a special door frame. Since the door wing is mounted on this panel, there is no additional mounting problem. Special PVC outer and aluminum inner cases are used for the rooms without panels. Since the sash is mounted on the frame, it is very easy to apply.
Heat TransferSealing is provided with a special rubber gasket surrounding the door. Resistance cable is used to prevent sticking, at the freezed keeping room doors case and it does not require a transformer as it has a resistance diode.
DimensionsIt is possible to produce in desired dimensions up to 100×200 cm net passage.

Mechanical Properties

FEATURESVALUES
Yield Strength of Sheet Surface (fct)min. 220N/mm²
Tensile Strength of Panelmin. 0,018 Mpa
High Temperature Transverse Tensile Modulesmin. 0,04 MPa
Core Material Shear Strength (fcv)min. 0,11 Mpa
Core Material Shear Modulus (G)min. 2 Mpa
Core Material Compressive Strength (σ10)min. 0,09 Mpa
Bending Moment Capacity and Rigidity – Flat (Mu)min. 2,3 kNm/m
Bending Moment Capacity and Rigidity – Reverse (Mu)min. 2 kNm/m
Torsional Stress Straight (σw)115 Mpa
Torsional Stress Reverse (σw)100 Mpa
Bending Moment Capacity on a Central Support – Straight2,95 kNm/m
Bending Moment Capacity on a Central Support – Inverse3 kNm/m
Torsional Stress Capacity on a Central Support – Straight133 Mpa
Torsional Stress Capacity on a Central Support – Reverse118 Mpa
PUR Thermal Conductivity Value (ʎ)max. 0,022 W/mK
Dimensional StabilityLevel DS(TH) 11
Inflammability Class (TS-EN 13501-1)C-s2,d0

Boyutsal Toleranslar

FEATURESVALUES
Thickness± %4
Length± 10 mm
Width± 2 mm
Deviation from Miter± 5 mm